Soniox STT-RT v5 is ahead on the Pipecat Dataset and final-text delay, and Smallest Pulse on time to first text. The Ocular Dataset is too close to call.
Last updated Methodology by Dileep Chagam
Each dot is one model. Bottom-left is best: fewer errors and a faster final transcript.
Pick Smallest Pulse for showing words while the caller is still talking (138ms sooner). Pick Soniox STT-RT v5 for accuracy on clean, scripted audio (1.11 points lower) and quick turn-taking once the caller stops (163ms sooner). For accuracy on real phone conversations, the gap is inside the margin of error, so neither is ahead.
Soniox STT-RT v5, 1.11 points lower
Too close to call: inside the margin of error
Smallest Pulse, 138ms sooner
Soniox STT-RT v5, 163ms sooner
Lower is better on every metric. The small figure is each model's place in the whole field. What each metric measures.
Smallest Pulse shows first text after 3.03s and final text after 773ms, and Soniox STT-RT v5 shows first text after 1.71s and final text after 79ms, on a bad turn (P95) across the same streamed turns.
| Measure | Model | P50 | P90 | P95 |
|---|---|---|---|---|
| Time to first text | Smallest Pulse | 1.06s | 2.25s | 3.03s |
| Soniox STT-RT v5 | 1.20s | 1.67s | 1.71s | |
| Final-text delay | Smallest Pulse | 201ms | 356ms | 773ms |
| Soniox STT-RT v5 | 38ms | 72ms | 79ms |
Place among the 17 models on each metric. Lower is better on all four.
| Metric | Pulse | STT-RT v5 |
|---|---|---|
| Pipecat Dataset WER | 3.66%13th of 17 | 2.54%8th of 17 |
| Ocular Dataset WER | 3.46%3rd of 17 | 3.92%6th of 17 |
| Time to first text | 1.06s5th of 15 | 1.20s9th of 15 |
| Final-text delay | 201ms10th of 17 | 38ms1st of 17 |
| Model | Pipecat clips | Ocular recordings | Turns timed | Failed |
|---|---|---|---|---|
| Smallest Pulse | 1,000 | 8 | 206 | 0 |
| Soniox STT-RT v5 | 1,000 | 8 | 200 | 6 |
Only clips with usable text count, so the two totals can differ. How WER is scored.
Soniox STT-RT v5 is more accurate on the public clips. On the 1,000 public Pipecat clips, Smallest Pulse scores 3.66% and Soniox STT-RT v5 2.54%, so Soniox STT-RT v5 makes fewer errors by 1.11 points. On the eight licensed Ocular recordings, Smallest Pulse scores 3.46% and Soniox STT-RT v5 3.92%, with likely ranges of 2.66 to 4.22% and 2.60 to 4.86%. The ranges overlap, so the difference is too close to call. Word error rate counts incorrect, missing, and extra words, so lower is better.
No. Soniox STT-RT v5 finishes the transcript 163ms sooner. Smallest Pulse has the final transcript 201ms after the speaker stops and Soniox STT-RT v5 38ms, at the median. Both are measured on the same 206 streamed turns.
Soniox STT-RT v5 finishes the transcript 163ms sooner, and the two are too close to call on real conversations. A voice agent cannot reply until the final transcript arrives, and the Ocular recordings are real conversations.
Yes, both return partial text before the speaker stops. Smallest Pulse shows first text after 1.06s and Soniox STT-RT v5 after 1.20s, at the median, so Smallest Pulse is 138ms sooner.