Soniox STT-RT v5 is ahead on final-text delay, and Speechmatics Linden on time to first text. The Pipecat Dataset and The Ocular Dataset are too close to call.
Last updated Methodology by Dileep Chagam
Each dot is one model. Bottom-left is best: fewer errors and a faster final transcript.
Pick Soniox STT-RT v5 for quick turn-taking once the caller stops (109ms sooner). Pick Speechmatics Linden for showing words while the caller is still talking (5ms sooner). For accuracy on clean, scripted audio and accuracy on real phone conversations, the gap is inside the margin of error, so neither is ahead.
Too close to call: inside the margin of error
Too close to call: inside the margin of error
Speechmatics Linden, 5ms sooner
Soniox STT-RT v5, 109ms sooner
Lower is better on every metric. The small figure is each model's place in the whole field. What each metric measures.
Soniox STT-RT v5 shows first text after 1.71s and final text after 79ms, and Speechmatics Linden shows first text after 2.52s and final text after 213ms, on a bad turn (P95) across the same streamed turns.
| Measure | Model | P50 | P90 | P95 |
|---|---|---|---|---|
| Time to first text | Soniox STT-RT v5 | 1.20s | 1.67s | 1.71s |
| Speechmatics Linden | 1.19s | 1.56s | 2.52s | |
| Final-text delay | Soniox STT-RT v5 | 38ms | 72ms | 79ms |
| Speechmatics Linden | 147ms | 192ms | 213ms |
Place among the 17 models on each metric. Lower is better on all four.
| Metric | STT-RT v5 | Linden |
|---|---|---|
| Pipecat Dataset WER | 2.54%8th of 17 | 2.46%7th of 17 |
| Ocular Dataset WER | 3.92%6th of 17 | 3.93%7th of 17 |
| Time to first text | 1.20s9th of 15 | 1.19s8th of 15 |
| Final-text delay | 38ms1st of 17 | 147ms8th of 17 |
| Model | Pipecat clips | Ocular recordings | Turns timed | Failed |
|---|---|---|---|---|
| Soniox STT-RT v5 | 1,000 | 8 | 200 | 6 |
| Speechmatics Linden | 998 | 8 | 194 | 12 |
Only clips with usable text count, so the two totals can differ. How WER is scored.
Soniox STT-RT v5 and Speechmatics Linden are too close to call on accuracy. On the 1,000 public Pipecat clips, Soniox STT-RT v5 scores 2.54% and Speechmatics Linden 2.46%, with likely ranges of 2.27 to 2.83% and 2.19 to 2.73%. The ranges overlap, so the difference is too close to call. On the eight licensed Ocular recordings, Soniox STT-RT v5 scores 3.92% and Speechmatics Linden 3.93%, with likely ranges of 2.60 to 4.86% and 2.94 to 5.19%. The ranges overlap, so the difference is too close to call. Word error rate counts incorrect, missing, and extra words, so lower is better.
Yes. Soniox STT-RT v5 finishes the transcript 109ms sooner. Soniox STT-RT v5 has the final transcript 38ms after the speaker stops and Speechmatics Linden 147ms, at the median. Both are measured on the same 206 streamed turns.
Soniox STT-RT v5 finishes the transcript 109ms sooner, and the two are too close to call on real conversations. A voice agent cannot reply until the final transcript arrives, and the Ocular recordings are real conversations.
Yes, both return partial text before the speaker stops. Soniox STT-RT v5 shows first text after 1.20s and Speechmatics Linden after 1.19s, at the median, so Speechmatics Linden is 5ms sooner.