All comparisons
GradiumSmallest

Gradium vs Smallest Pulse

Smallest Pulse is ahead of Gradium on the Pipecat Dataset, time to first text and final-text delay. The Ocular Dataset is too close to call.

Last updated Methodology by Dileep Chagam

Compare

Accuracy vs speed

Each dot is one model. Bottom-left is best: fewer errors and a faster final transcript.

Top half on bothBest picks
Final-text delay P50 (ms)
Pipecat Dataset WER (%)
Shaded box: top half on both measures. Dotted line: no other model is both more accurate and faster.
Verdict

Which to pick

Smallest Pulse is the better pick over Gradium on every measure that separates them: accuracy on clean, scripted audio (2.82 points lower), showing words while the caller is still talking (648ms sooner) and quick turn-taking once the caller stops (11ms sooner). For accuracy on real phone conversations, the gap is inside the margin of error, so neither is ahead.

Head to head

The four metrics, side by side

Pipecat Dataset WER
Gradium
6.48%17th
Smallest Pulse
3.66%13th

Smallest Pulse, 2.82 points lower

Ocular Dataset WER
Gradium
4.45%12th
Smallest Pulse
3.46%3rd

Too close to call: inside the margin of error

Time to first text
Gradium
1.71s12th
Smallest Pulse
1.06s5th

Smallest Pulse, 648ms sooner

Final-text delay
Gradium
212ms11th
Smallest Pulse
201ms10th

Smallest Pulse, 11ms sooner

Lower is better on every metric. The small figure is each model's place in the whole field. What each metric measures.

WER · Word error rate
Share of words the model got wrong: replaced, missing or added. Lower is better.
Pipecat Dataset
1,000 short public clips from Pipecat's STT benchmark dataset.
Ocular Dataset
8 recordings from 4 real phone conversations, licensed from Ocular.
TTFT · Time to first text
How long after the audio starts streaming until the first words appear.
TTFS · Final-text delay
How long after the caller stops until the full transcript arrives. A voice agent waits for this before it replies.
Latency

First text and final text, at three percentiles

Gradium shows first text after 7.32s and final text after 280ms, and Smallest Pulse shows first text after 3.03s and final text after 773ms, on a bad turn (P95) across the same streamed turns.

MeasureModelP50P90P95
Time to first textGradium1.71s4.05s7.32s
Smallest Pulse1.06s2.25s3.03s
Final-text delayGradium212ms266ms280ms
Smallest Pulse201ms356ms773ms
P50 / P90 / P95 · Typical, slow and slowest turns
Half of turns are faster than P50. Only 1 in 10 is slower than P90, and 1 in 20 slower than P95.
Ranking

How each ranks among all 17 models

Place among the 17 models on each metric. Lower is better on all four.

MetricGradiumPulse
Pipecat Dataset WER6.48%17th of 173.66%13th of 17
Ocular Dataset WER4.45%12th of 173.46%3rd of 17
Time to first text1.71s12th of 151.06s5th of 15
Final-text delay212ms11th of 17201ms10th of 17
Coverage

How much audio each model was tested on

ModelPipecat clipsOcular recordingsTurns timedFailed
Gradium1,00081980
Smallest Pulse1,00082060

Only clips with usable text count, so the two totals can differ. How WER is scored.

Questions

Frequently asked questions

Which is more accurate, Gradium or Smallest Pulse?

Smallest Pulse is more accurate on the public clips. On the 1,000 public Pipecat clips, Gradium scores 6.48% and Smallest Pulse 3.66%, so Smallest Pulse makes fewer errors by 2.82 points. On the eight licensed Ocular recordings, Gradium scores 4.45% and Smallest Pulse 3.46%, with likely ranges of 3.17 to 5.90% and 2.66 to 4.22%. The ranges overlap, so the difference is too close to call. Word error rate counts incorrect, missing, and extra words, so lower is better.

Is Gradium faster than Smallest Pulse?

No. Smallest Pulse finishes the transcript 11ms sooner. Gradium has the final transcript 212ms after the speaker stops and Smallest Pulse 201ms, at the median. Both are measured on the same 206 streamed turns.

Is Gradium or Smallest Pulse better for voice agents?

Smallest Pulse finishes the transcript 11ms sooner, and the two are too close to call on real conversations. A voice agent cannot reply until the final transcript arrives, and the Ocular recordings are real conversations.

Do Gradium and Smallest Pulse stream text while the speaker is talking?

Yes, both return partial text before the speaker stops. Gradium shows first text after 1.71s and Smallest Pulse after 1.06s, at the median, so Smallest Pulse is 648ms sooner.