Soniox STT-RT v5 is ahead of Gradium on the Pipecat Dataset, time to first text and final-text delay. The Ocular Dataset is too close to call.
Last updated Methodology by Dileep Chagam
Each dot is one model. Bottom-left is best: fewer errors and a faster final transcript.
Soniox STT-RT v5 is the better pick over Gradium on every measure that separates them: accuracy on clean, scripted audio (3.93 points lower), showing words while the caller is still talking (510ms sooner) and quick turn-taking once the caller stops (174ms sooner). For accuracy on real phone conversations, the gap is inside the margin of error, so neither is ahead.
Soniox STT-RT v5, 3.93 points lower
Too close to call: inside the margin of error
Soniox STT-RT v5, 510ms sooner
Soniox STT-RT v5, 174ms sooner
Lower is better on every metric. The small figure is each model's place in the whole field. What each metric measures.
Gradium shows first text after 7.32s and final text after 280ms, and Soniox STT-RT v5 shows first text after 1.71s and final text after 79ms, on a bad turn (P95) across the same streamed turns.
| Measure | Model | P50 | P90 | P95 |
|---|---|---|---|---|
| Time to first text | Gradium | 1.71s | 4.05s | 7.32s |
| Soniox STT-RT v5 | 1.20s | 1.67s | 1.71s | |
| Final-text delay | Gradium | 212ms | 266ms | 280ms |
| Soniox STT-RT v5 | 38ms | 72ms | 79ms |
Place among the 17 models on each metric. Lower is better on all four.
| Metric | Gradium | STT-RT v5 |
|---|---|---|
| Pipecat Dataset WER | 6.48%17th of 17 | 2.54%8th of 17 |
| Ocular Dataset WER | 4.45%12th of 17 | 3.92%6th of 17 |
| Time to first text | 1.71s12th of 15 | 1.20s9th of 15 |
| Final-text delay | 212ms11th of 17 | 38ms1st of 17 |
| Model | Pipecat clips | Ocular recordings | Turns timed | Failed |
|---|---|---|---|---|
| Gradium | 1,000 | 8 | 198 | 0 |
| Soniox STT-RT v5 | 1,000 | 8 | 200 | 6 |
Only clips with usable text count, so the two totals can differ. How WER is scored.
Soniox STT-RT v5 is more accurate on the public clips. On the 1,000 public Pipecat clips, Gradium scores 6.48% and Soniox STT-RT v5 2.54%, so Soniox STT-RT v5 makes fewer errors by 3.93 points. On the eight licensed Ocular recordings, Gradium scores 4.45% and Soniox STT-RT v5 3.92%, with likely ranges of 3.17 to 5.90% and 2.60 to 4.86%. The ranges overlap, so the difference is too close to call. Word error rate counts incorrect, missing, and extra words, so lower is better.
No. Soniox STT-RT v5 finishes the transcript 174ms sooner. Gradium has the final transcript 212ms after the speaker stops and Soniox STT-RT v5 38ms, at the median. Both are measured on the same 206 streamed turns.
Soniox STT-RT v5 finishes the transcript 174ms sooner, and the two are too close to call on real conversations. A voice agent cannot reply until the final transcript arrives, and the Ocular recordings are real conversations.
Yes, both return partial text before the speaker stops. Gradium shows first text after 1.71s and Soniox STT-RT v5 after 1.20s, at the median, so Soniox STT-RT v5 is 510ms sooner.